DH1000-C Plug-in/Insertion Electromagnetic Flow Meter
DH1000-C Plug-in/Insertion Electromagnetic Flow Meter / DH1000-C
Accuracy: 1.5% Medium: Conductive liquid , slurry Signal output: 4-20mA, pulse Communication protocol : RS485, Hart
SHARE :
Show Details

                               Insertion type magnetic flowmeter

Reliable,                High Accuracy Flowmeter water Applications.

Feature:

 

1.Smart design, enabling display of medium flow direction and empty tube

 

2.signal;

 

3.Two styles featured: compact and separate type;

 

4.Coming available in multiple models, such as tube-shaped and insertion model
             Powered by AC or DC in smart way, in two-wire mode, or using lithium cell

 

5.Wide flow range (30:1) and low initial flow rate for measurement (0.2m/s);

 

6.Adoption of EEPROM, ensuring impregnably secure storage of measurement
              & calculation data;

 

7.Displaying second, minute, hour, day, month and year;

 

8.Equipped with the communication interface RS-485 compatible with the protocol 
              MODBUS and the HART
compatible communication interface;

 

9.Simplified and tested structure; without movable parts and no intercepting or 
             choking parts, thereby guaranteeing absence     of pressure loss or fluid blockage;

 

10.Nonexistence of mechanical inertia leading to rapid response and excellent stability; 
              capable of being applied in automatic     detection, adjustment and program control system;

 

11.Accuracy in measurement not subject to the kind, temperature, viscosity, density, 
               pressure and other physical properties     of the medium;

 

12.Diverse mixes of polytetrafluoroethylene or rubber linings and electrode materials 
              (e.g. Hc, Hb, 316L and Ti etc.) adapting the product to various media;

 

13.Suitable for measuring a variety of corrosive fluids, including strong acid, 
               strong alkali, and saline solution etc.;

 

    
Data sheet
<

Technical Performance Parameters
  Caliver   DN3~DN3000mm
  Nominal Pressure  0.6~4.0MPa(special pressure can be made to)
  Accuracy  &plusmn;0.5%,&plusmn;0.3%or&plusmn;0.2% are selectable
  Liner material  Teflon,PFA,F46,Neoprene,Polyurethane
  Electrode Type  General type ,scraper type and replaceable type
  Electrode material  Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,Stainless steel covered with tungsten carbide
  Medium Temperature Integral type -20&deg;C~+60&deg;C
 Remote type Neoprene & Polyurethane Liner -10&deg;C~+80&deg;C
 PTFE Liner /PFA Liner /F46 Liner                -10&deg;C~+160&deg;C
  Ambient Temperature  -25&deg;C ~+ 60&deg;C
  Ambient Humidity  5~100%RH(relative humidity)
  Medium Electrical conductivity  &ge;5&mu; s/cm
  Measuring Range  1500:1,flow rate<15m/s
  Structure type   Integral type,remote type,submersible type,ex-proof type
  Protection Class  IP65,IP68(optional)
  Ex-proof Mark  ExmdT4
  Product Standard  JB/T 9248-1999 Electormagnetic Flowmeter

 